Connections made in 3D AE give access violation error in 3D 2016.00

$
0
0
Application:
Known Issue ID:
10767

Problem description

Projects created with PLAXIS 3D AE or PLAXIS 3D Classic that contain custom connections will encounter problems during the regeneration of the staged construction settings in the PLAXIS 3D 2016 version.
This problem occurs both with custom connections between two plates and between a plate and a beam.

As a result, an access violation bugreport appears when trying to switch to any of the green modes (Mesh, Flow conditions, Staged construction).

Solution

In order to be able to continue working in the existing project with PLAXIS 3D 2016.00 version follow the steps below:

  1. Open project in 3D Classic Input program
  2. Delete any custom connections in staged construction mode
  3. Save the project with a different name (e.g. myproject_no_connections.p3d)
  4. Open project in 3D 2016.00 version
  5. Re-create the custom connection(s) manually

Alternatively, you can use PLAXIS 3D Classic for your project.

Plaxis is working on a solution for this issue.