Quantcast
Channel: Knowledge Base Articles – Plaxis
Viewing all articles
Browse latest Browse all 329

[Solved] Staged construction/Flow condition settings might not be loaded correctly in 2D 2017

$
0
0

The problem is already fixed for PLAXIS 2D 2017.01

When using PLAXIS 2D 2017.00 this workaround can be followed:

  1. Delete all Safety phases
  2. Execute the following command in staged construction mode:
    tabulate Phases "Number"
  3. Count the number of phases being omitted by comparing them with the value for the .Number property
  4. Add an equal number of dummy phases to the number corresponding to the omitted phases starting from the Initial Phase
  5. Set the dummy phases to Not calculate status
  6. Re-create the Safety phases

For example, in the following project eleven (11) dummy phases should be added in order to be consistent with the number of the omitted phases:

Add_dummy_phases_example

The post [Solved] Staged construction/Flow condition settings might not be loaded correctly in 2D 2017 appeared first on Plaxis.